Document Number: 93506 For technical questions, contact: ind-modules@vishay.com
www.vishay.com
Revision: 29-Sep-08 3
25F(R) Series
Standard Recovery Diodes
(Stud Version), 25 A
Vishay High Power Products
Note
• The table above shows the increment of thermal resistance R
thJC
when devices operate at different conduction angles than DC
Fig. 1 - Current Ratings Characteristics Fig. 2 - Current Ratings Characteristics
Fig. 3 - Forward Power Loss Characteristics
ΔR
thJC
CONDUCTION
CONDUCTION ANGLE SINUSOIDAL CONDUCTION RECTANGULAR CONDUCTION TEST CONDITIONS UNITS
180° 0.28 0.24
T
J
= T
J
maximum K/W
120° 0.39 0.41
90° 0.50 0.54
60° 0.73 0.75
30° 1.20 1.21
100
110
120
130
140
150
160
170
180
0 5 10 15 20 25 30
30°
60°
90°
120°
180°
Maximum Allowable Case Temperature (°C)
Conduction Angle
Average Forward Current (A)
25F(R) Series
R (DC) = 1.5 K/W
thJC
100
110
120
130
140
150
160
170
180
0 5 10 15 20 25 30 35 40 45
DC
30°
60°
90°
120°
180°
Maximum Al l owable Case Temperature (°C)
Conduction Period
Average Forward Current (A)
25F(R) Series
R (DC) = 1.5 K/W
thJC
0 25 50 75 100 125 150 175
Maximum Allowable Ambient Temperature (°C)
R
=
1
K
/
W
-
D
e
l
t
a
R
t
h
S
A
2
K
/
W
3
K
/
W
4
K
/
W
6
K
/
W
8
K
/
W
1
2
K
/
W
2
0K
/
W
4
0
K
/
W
0
5
10
15
20
25
30
35
0 5 10 15 20 25 30
Average Forward Current (A)
RMS Limit
Maximum Average Forward Power Loss (W)
Conduc t ion Angle
180°
120°
90°
60°
30°
25F(R) Series
T = 175°C
J
Comentarios a estos manuales