Vista de pagina 3
649
PM100DSA120
Intellimod™ Module
Single Phase IGBT Inverter Output
100 Amperes/1200 Volts
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Electrical and Mechanical Characteristics, T
j
= 25°C unless otherwise specified
Characteristics Symbol Test Conditions Min. Typ. Max. Units
Control Sector
Over Current Trip Level Inverter Part OC -20°C T 125°C 145 230 Amperes
Short Circuit Trip Level Inverter Part SC -20°C T 125°C 200 340 Amperes
Over Current Delay Time t
off(OC)
V
D
= 15V 5 µS
Over Temperature Protection OT Trip Level 100 110 120 °C
OT
R
Reset Level 85 95 105 °C
Supply Circuit Under Voltage Protection UV Trip Level 11.5 12.0 12.5 Volts
UV
R
Reset Level 12.5 Volts
Supply Voltage V
D
Applied between V
P1
-V
PC
, V
N1
-V
NC
13.5 15 16.5 Volts
Circuit Current I
D
V
D
= 15V, V
CIN
= 5V, V
N1
-V
NC
—1926mA
V
D
= 15V, V
CIN
= 5V, V
XP1
-V
XPC
—1926mA
Input ON Threshold Voltage V
CIN(on)
Applied between 1.2 1.5 1.8 Volts
Input OFF Threshold Voltage V
CIN(off)
C
P1
-V
PC
, C
N1
-V
NC
1.7 2.0 2.3 Volts
PWM Input Frequency f
PWM
3-B Sinusoidal 15 20 kHz
Fault Output Current I
FO(H)
V
D
= 15V, V
FO
= 15V 0.01 mA
I
FO(L)
V
D
= 15V, V
FO
= 15V 10 15 mA
Minimum Fault Output Pulse Width t
FO
V
D
= 15V 1.0 1.8 mS
SXR Terminal Output Voltage V
SXR
T
j
125°C, Rin = 6.8 kV (S
PR
, S
NR
) 4.5 5.1 5.6 Volts
Vista de pagina 3