559
PM75RSA060
Intellimod™ Module
Three Phase + Brake IGBT Inverter Output
75 Amperes/600 Volts
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Thermal Characteristics
Characteristic Symbol Condition Min. Typ. Max. Units
Junction to Case Thermal Resistance R
th(j-c)Q
Each Inverter IGBT — — 0.4 °C/Watt
R
th(j-c)D
Each Inverter FWDi — — 1.0 °C/Watt
R
th(c-f)Q
Each Brake IGBT — — 0.6 °C/Watt
R
th(c-f)D
Each Brake FWDi — — 1.5 °C/Watt
Contact Thermal Resistance R
th(c-f)
Case to Fin Per Module, — — 0.027 °C/Watt
Thermal Grease Applied
Recommended Conditions for Use
Characteristic Symbol Condition Value Units
Supply Voltage V
CC
Applied across P-N Terminals 0 ~ 400 Volts
V
D
Applied between V
UP1
-V
UPC
, 15 ± 1.5 Volts
V
N1
-V
NC
, V
VP1
-V
VPC
, V
WP1
-V
WPC
Input ON Voltage V
CIN(on)
Applied between 0 ~ 0.8 Volts
Input OFF Voltage V
CIN(off)
U
P
, V
P
, W
P
, U
N
, V
N
, W
N
, B
r
4.0 ~ V
D
Volts
PWM Input Frequency f
PWM
Using Application Circuit 5 ~ 20 kHz
Minimum Dead Time t
DEAD
Input Signal ≥ 2.5 µS