Ch-technology PS22A74 Manual de usuario Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 8
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
PS22A74
Intellimod™ Module
Dual-In-Line Intelligent Power Module
15 Amperes/1200 Volts
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272
4 Rev. 08/09
Thermal Characteristics, T
j
= 25°C unless otherwise specied
Characteristic Symbol Condition Min. Typ. Max. Units
Thermal Resistance Junction to Case R
th(j-C)Q
IGBT Part (Per 1/6 Module) 1.15 °C/Watt
Thermal Resistance Junction to Case R
th(j-C)D
FWDi Part (Per 1/6 Module) 1.36 °C/Watt
Recommended Conditions for Use
Characteristic Symbol Condition Min. Typ. Max. Units
Supply Voltage V
CC
Applied between P-NU, NV, NW 350 600 800 Volts
Control Supply Voltage V
D
Applied between V
P1
-V
PC
, V
N1
-V
NC
13.5 15.0 16.5 Volts
V
DB
Applied between V
UFB
-V
UFS
,
13.0 15.0 18.5 Volts
V
VFB
-V
VFS
, V
WFB
-V
WFS
Control Supply Variation
ΔV
D
, ΔV
DB
-1 1 V/µs
Arm Shoot-through t
DEAD
For Each Input Signal, T
C
100°C 3.3 µs
Blocking Time
PWM Input Frequency f
PWM
T
C
100°C, T
j
125°C 15 kHz
Allowable rms Current* I
O
V
CC
= 600V, V
D
= 15V, 5.5 Arms
f
C
= 15kHz, PF = 0.8, Sinusoidal PWM,
T
j
125°C, T
C
100°C
Minimum Input P
WIN(on)
** µs
Pulse Width P
WIN(off)***
I
C
5A 350 V
CC
800V, 13.5 V
D
16.5V, µs
15 I
C
25.5A 13.5 V
DB
16.5V, -20°C T
C
100°C, µs
N-line Wiring Inductance Less Than 10nH
V
NC
Variation V
NC
Between V
NC
-NU, NV, NW (Including Surge) -5.0 5.0 Volts
* The allowable rms current value depends on the actual application conditions.
**If input signal ON pulse is less than P
WIN(on)
, the device may not respond.
***The IPM may fail to respond to an ON pulse if the preceeding OFF pulse is less than P
WIN(off)
.
Delayed Response Against Shorter Input OFF Signal Than P
WIN
(off)
, P-side only
t2
t1
P-SIDE
CONTROL INPUT
INTERNAL
IGBT GATE
OUTPUT
CURRENT I
C
Solid Line – OFF Pulse Width > P
WIN(off)
: Turn ON time t1.
Dotted Line – OFF Pulse Width < P
WIN(off)
: Turn ON time t2.
Vista de pagina 4
1 2 3 4 5 6 7 8

Comentarios a estos manuales

Sin comentarios