Ch-technology ST1200C..KP Series Manual de usuario Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 8
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
www.vishay.com For technical questions, contact: ind-modules@vishay.com
Document Number: 94394
4 Revision: 30-Apr-08
ST1200C..KP Series
Vishay High Power Products
Phase Control Thyristors
(Hockey PUK Version), 1650 A
Fig. 1 - Current Ratings Characteristics
Fig. 2 - Current Ratings Characteristics
Fig. 3 - Current Ratings Characteristics
Fig. 4 - Current Ratings Characteristics
Fig. 5 - On-State Power Loss Characteristics
Fig. 6 - On-State Power Loss Characteristics
Average On-state Current (A)
Maximum Allowable Heatsink Temperature (°C)
40
50
60
70
80
90
100
110
120
130
0 200 400 600 800 1000 1200
30°
60°
90°
120°
180°
Conduction Angle
ST1200C..K Series
(Single Side Cooled)
R (DC) = 0.042 K/W
thJ-hs
Maximum Allowable Heatsink Temperature (°C)
Average On-state Current (A)
20
30
40
50
60
70
80
90
100
110
120
130
0 400 800 1200 1600 2000
DC
30°
60°
90°
120°
180°
Conduction Period
ST1200C..K Series
(Single Side Cooled)
R (DC) = 0.042 K/W
thJ-hs
Average On-state Current (A)
Maximum Allowable Heatsink Temperature (°C)
30
40
50
60
70
80
90
100
110
120
130
0 400 800 1200 1600 2000
30°
60°
90°
120°
180°
Conduction Angle
ST1200C..K Series
(Double Side Cooled)
R (DC) = 0.021 K/W
thJ-hs
Average On-state Current (A)
Maximum Allowable Heatsink Temperature (°C)
20
30
40
50
60
70
80
90
100
110
120
130
0 600 1200 1800 2400 3000 3600
DC
30°
60°
90°
120°
180°
Conduction Period
ST1200C..K Series
(Double Side Cooled)
R (DC) = 0.021 K/W
thJ-hs
Average On-state Current (A)
Maximum Allowable Heatsink Temperature (°C)
0
500
1000
1500
2000
2500
3000
3500
4000
0 400 800 1200 1600 2000
180°
120°
90°
60°
30°
RMS Limit
Conduction Angle
ST1200C..K Series
T = 125°C
J
Maximum Allowable Heatsink Temperature (°C)
Average On-state Current (A)
0
1000
2000
3000
4000
5000
0 600 1200 1800 2400 3000 3600
DC
180°
120°
90°
60°
30°
RMS Limit
Conduction Period
ST1200C..K Series
T = 125°C
J
Vista de pagina 4
1 2 3 4 5 6 7 8

Comentarios a estos manuales